2025 Generac Mobile Stationary Generators SG230 Features may include:
Enclosure Generac manufactures its own enclosures, ensuring each unit combines the highest level of durability, noise reduction, weather resistance, and streamlined design. Spark-Ignited Engine Generac builds its spark-ignited engines from the block up utilizing advanced engineering expertise. Industrial Alternator Generac industrial alternators are machine wound, machine inserted, and machine varnished for the ultimate in consistency. POWERMANAGER® Controller Generac engineers its generator controls with safety and convenience as top priorities.
Highlights
Location Muncy, Pennsylvania Year 2025 Make Generac Mobile Model Stationary Generators SG230 Fuel Type Natural Gas Status Available Width Open Set (Includes Exhaust Flex): 57.1 in (1,450 mm) | Weather Protected Enclosure: 57.5 in (1,461 mm) | Level 1 Sound Attenuated Enclosure: 57.5 in (1,461 mm) | Level 2 Sound Attenuated Enclosure: 57.5 in (1,461 mm)) | Level 3 Sound Attenuated Enclosure: 63.7 in (1,618 mm) Height Open Set (Includes Exhaust Flex): 67.9 in (1,725 mm) | Weather Protected Enclosure: 77.8 in (1,976 mm) | Level 1 Sound Attenuated Enclosure: 77.8 in (1,976 mm) | Level 2 Sound Attenuated Enclosure: 111.3 in (2,827 mm) | Level 3 Sound Attenuated Enclosure: 128.9 in (3,274 mm)
Specifications
Year 2025 Manufacturer Generac Mobile Model Name Stationary Generators Trim Name SG230 Generic Type (Primary) General Engine Manufacturer Generac Cylinder Liners 6 Engine Type In-line Displacement 864.71 in3 (14.2 L) Bore 5.31 in (135 mm) Stroke 6.50 in (165 mm) Compression Ratio 9.5:1 Intake Design Air Method: Turbocharged/Aftercooled Ignition Electronic Governor Electronic Cooling Type: Pressurized Closed Recovery Engine Power Standby-Demand Response/Prime Horsepower at Rated kW: 344 hp / 310 hp | Standby-Demand Response/Prime Three-Phase 120/208 VAC @0.8pf: 230 kW/288 kVA, 799 Amps / 207 kW/259 kVA, 719 Amps | Standby-Demand Response/Prime Three-Phase 120/240 VAC @0.8pf: 230 kW/288 kVA, 692 Amps / 207 kW/259 kVA, 623 Amps | Standby-Demand Response/PrimeThree-Phase 277/480 VAC @0.8pf: 230 kW/288 kVA, 346 Amps / 207 kW/259 kVA, 312 Amps | Standby-Demand Response/PrimeThree-Phase 346/600 VAC @0.8pf: 230 kW/288 kVA, 277 Amps / 207 kW/259 kVA, 249 Amps Rated Engine Speed Standby-Demand Response/Prime: 1,800 RPM/ 1,800 RPM Fuel System Carburetor: Down Draft | NPT Flexible Fuel Line Fuel Type Natural Gas Fuel Usage, 100% Load Standby-Demand Response/Prime 25%: 990 scfh (28.0 m3/hr) / 960 scfh (27.2 m3/hr) | Standby-Demand Response/Prime 50%: 1,560 scfh (44.2 m3/hr) / 1,440 scfh (40.8 m3/hr) | Standby-Demand Response/Prime 75%: 2,400 scfh (68.0 m3/hr) / 1,980 scfh (56.1 m3/hr) | Standby-Demand Response/Prime 100%: 3,000 scfh (84.9 m3/hr) / 2,640 scfh (69.7 m3/hr) Battery Size: See Battery Index 0161970SBY | Voltage: 24 VDC Battery Charger Input Alternator: 57.5 A | 120V GFCI and 240V Outlets Electrical System Voltage: 24 VDC | Ground Polarity: Negative (-) Alternator Standard Model: K0250124Y21 | Poles: 4 | Field Type: Revolving | Insulation Class - Rotor: H | Insulation Class - Stator: H | Total Harmonic Distortion: <5% (3-Phase) | Telephone Interference Factor (TIF): <50 | Standard Excitation: Permanent Magnet | Bearings: Single Sealed Ball | Coupling: Direct via Flexible Disc | Voltage Regulator Type: Full Digital | Regulation Accuracy (Steady State): ±0.25% | Alternator Upsizing | Anti-Condensation Heater | Tropical Coating Operating Conditions Frequency Regulation (Steady State): ±0.25% Operating Speed Fan: 1,894 RPM | Standby-Demand Response/Prime Piston: 1,950 ft/min (594 m/min) / 1,950 ft/min (594 m/min) Operating Temperature, Maximum Standby-Demand Response/Prime Maximum Operating Ambient Temperature: 122 °F (50 °C) / 122 °F (50 °C) | Standby-Demand Response/PrimeMaximum Operating Ambient Temperature (Before Derate): See Bulletin No. 0199270SSD / See Bulletin No. 0199270SSD | Standby-Demand Response/Prime Exhaust Temp (Rated Output - Post Silencer): 1,340 °F (727 °C) / 1,318 °F (714 °C) Pump Type Oil: Gear Oil Filter Type: Full-Flow Cartridge Hydraulic Flow Standby-Demand Response/Prime Coolant Flow: 90 gpm (340.7 Lpm) / 90 gpm (340.7 Lpm) Airflow Standby-Demand Response/Prime Air Flow (Fan Air Flow Across Radiator): 10,078 cfm (285.4 m3/min) / 10,078 cfm (285.4 m3/min) | Standby-Demand Response/Prime Flow at rated power: 480 cfm (13.6 m3/min) / 438 cfm (12.4 m3/min) | Standby-Demand Response/Prime Exhaust Flow (Rated Output): 1,600 cfm (45 m3/min) / 1,442 cfm (41 m3/min) Maximum Pressure Operating Fuel Pressure: 7 - 11 in H2O (1.7 - 2.7 kPa) | Standby-Demand Response/Prime Maximum Additional Radiator Backpressure: 0.5 in H2O (0.12 kPa) / 0.5 in H2O (0.12 kPa) | Standby-Demand Response/Prime BMEP: 175 psi (1,205 kPa) / 157 psi (1,085 kPa) | Standby-Demand Response/Prime Max. Backpressure (Post Silencer): 0.75 inHg (2.54 kPa) / 0.75 inHg (2.54 kPa) Dimensions Fan Diameter: 30 in (762 mm) Length Open Set (Includes Exhaust Flex): 136.0 in (3,454 mm) | Weather Protected Enclosure: 174.7 in (4,437 mm) | Level 1 Sound Attenuated Enclosure: 200.2 in (5,085 mm) | Level 2 Sound Attenuated Enclosure: 180.6 in (4,587 mm) | Level 3 Sound Attenuated Enclosure: 207.3 in (5,265 mm) Width Open Set (Includes Exhaust Flex): 57.1 in (1,450 mm) | Weather Protected Enclosure: 57.5 in (1,461 mm) | Level 1 Sound Attenuated Enclosure: 57.5 in (1,461 mm) | Level 2 Sound Attenuated Enclosure: 57.5 in (1,461 mm)) | Level 3 Sound Attenuated Enclosure: 63.7 in (1,618 mm) Height Open Set (Includes Exhaust Flex): 67.9 in (1,725 mm) | Weather Protected Enclosure: 77.8 in (1,976 mm) | Level 1 Sound Attenuated Enclosure: 77.8 in (1,976 mm) | Level 2 Sound Attenuated Enclosure: 111.3 in (2,827 mm) | Level 3 Sound Attenuated Enclosure: 128.9 in (3,274 mm) Oil capacity Engine: 36.2 gal (34.3 L) Cooling System Standby-Demand Response/Prime Coolant System Capacity:15 gal (54.9 L) / 15 gal (54.9 L) Weight Open Set (Includes Exhaust Flex): 5,883 - 6,031 lbs (2,668 - 2,735 kg) | Weather Protected Enclosure Steel: 7,448 - 7,596 lbs (3,378 - 3,445 kg) | Weather Protected Enclosure Aluminum: 6,654 - 6,801 lbs (3,018 - 3,084 kg) | Level 1 Sound Attenuated Enclosure Steel: 7,911 - 8,059 lbs (3,588 - 3,655 kg) | Level 1 Sound Attenuated Enclosure Aluminum: 6,853 - 7,000 lbs (3,108 - 3,175 kg) | Level 2 Sound Attenuated Enclosure Steel: 8,484 - 8,632 lbs (3,848 - 3,915 kg) | Level 2 Sound Attenuated Enclosure Aluminum: 7,099 - 7,247 lbs (3,220 - 3,287 kg) | Level 3 Sound Attenuated Enclosure: 10,840 - 10,990 lbs (4,916 - 4,984 kg) Features Number of Main Bearings: 7 | Lifter Type: Solid | Fan Type: Pusher | Engine Coolant Heater | Baseframe Cover/Rodent Guard | 2 Stage Air Cleaner | Oil Heater | Air Filter Restriction Indicator | Radiator Stone Guard (Open Set Only) | Level 1 Fan and Belt Guards (Enclosed Units Only) | 10A UL Listed Battery Charger | Battery Warmer | Demand Response Rating | Extended Factory Testing (3-Phase Only) | 12 Position Load Center | Vapor Recovery Heater | Weather Protected Enclosure | Level 1 Sound Attenuated | Level 2 Sound Attenuated | Level 2 Sound Attenuated with Motorized Dampers | Level 3 Sound Attenuated (Steel Only) | Up to 200 MPH Wind Load Rating (Contact Factory for Availability) | AC/DC Enclosure Lighting Kit | Enclosure Heaters (with Motorized Dampers Only) | Door Open Alarm Switch | NFPA 110 Level 1 Compliant 21-Light Remote Annunciator | Remote Relay Assembly (8 or 16) | Remote E-Stop (Break Glass-Type, Surface Mount) | Remote E-Stop (Red Mushroom-Type, Surface Mount) | Remote E-Stop (Red Mushroom-Type, Flush Mount) | 10A Engine Run Relay | Ground Fault Annunciator | 100 dB Alarm Horn | Damper Alarm Contacts (with Motorized Dampers Only) Construction Material Connecting Rods: Steel Alloy | Cylinder Head: Cast Iron | Cylinder Liners: Ductile Iron | Piston Type: Aluminum | Crankshaft Type: Ductile Iron | Intake Valve Material: Special Heat-Resistant Steel | Exhaust Valve Material: High Temperature Steel Alloy | Hardened Valve Seats: High Temperature Steel Alloy | Steel Enclosure | Aluminum Enclosure Warranty Standby Gensets Only: 2 Year Extended Limited Warranty, 5 Year Extended Limited Warranty, 7 Year Extended Limited Warranty, 10 Year Extended Limited Warranty