Electric
Electrical
Amperes: 2,000-2,500-3,200 | Poles: 3-4/3-4 | Load Side, Normal and Standby Source: (6) 1/0-750 MCM / (9) 1/0-750 MCM | Neutral Connection: (24) 4/0-500 MCM / (36) 4/0-500 MCM | UL 1008 Withstand and Closing Ratings Ampere Rating, Rating When Used with Upstream Circuit Breaker (3 Cycle 600 V-30 Cycle 600 V): 100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/-85 kA
Operational
Operating Temperature, Maximum
-4 ° to 158 °F (-20 ° to 70 °C)
Dimensions
Height
2,000-2,500-3,200: 90.0 in (2,286 mm) / 90.0 in (2,286 mm)
Width
2,000-2,500-3,200: 64.0 in (1,626 mm) / 64.0 in (1,626 mm)
Depth, Maximum
2,000-2,500-3,200: 60.0 in (1,524 mm) / 75.0 in (1,905 mm)
Weights
Weight
2,000-2,500-3,200: 3,100 lbs (1,409 kg)- 4,100 lbs (1,864 kg)/3,700 lbs (1,682 kg)- 4,700 lbs (2,136 kg) / 4,700 lbs (2,136 kg)-5,700 lbs/(2,591 kg)-5,500 lbs (2,500 kg)- 6,500 (2,955)
Features
Features
Enclosure Type (NEMA): 1-3R/1-3R / 1-3R/1-3R | Single Motion Rack-out with Doors Closed | Front Access | Cable Entry is Side, Rear, Top, and Bottom | Isolated Compartments for Improved Safety | ATC-900 Controller | Mimic Diagram with Source Available and Connected LED Indication | Field-Selectable Multi-tap Transformer Panel Permits Operation on a Wide Range of System Voltages | Event Logging and Recording 450 Time-Stamped Events | System TEST Pushbutton | Programmable Plant Exerciser | Modbus® RTU | Three Phase Under and Over Voltage Sensing on Normal and Emergency Sources, Plus Load | Under and Over Frequency Sensing on Normal, Emergency, and Load | Three Phase Sequence Sensing for Phase Sensitive Loads | Three Phase Voltage Unbalance and Loss Sensing | Source Available: Source-1 Present, 1-N.O. and 1-N.C. /Source-2 Present, 1-N.O. and 1-N.C. | Switch Position: Source-1 Position, 1-N.O. and 1-N.C. / Source-2 Position, 1-N.O. and 1-N.C. | Up to 20 Parameters Available with Expandable Input/Output Modules | Monitor Mode | Bypass Timers | Lockout | Manual Retransfer On/Off | Manual Retransfer | Slave In | Remote Engine Test | Preferred Source Selection | Go to Emergency | Emergency Inhibit | ATS on Bypass | Go to Neutral | Load Sequence | Selective Load Shed | Load Bank Control | Pre/Post-Transfer | Pre-Transfer | User Remote Control | Source 1 Available (Standard) | Source 2 Available (Standard) | Source 1 Connected | Source 2 Connected | ATS Not in Automatic | General Alarm | ATS in Test | Engine Test Aborted | Cooldown in Process | Engine Start Contact Status | Generator 1 Start Status | Generator 2 Start Status | Emergency Inhibit On | ATS On Bypass