Electric
Electrical
Fixed-Mount Open with Inphase or Delayed Transition Amperes: 2,000/2,500–3,200 | Fixed-Mount Open with Inphase or Delayed Transition 2,000/2,500/3,200 Poles: 3-4/3-4 | Fixed-Mount Open with Inphase or Delayed Transition 2,000/2,500/3,200 Load Side, Normal and Standby Source: (6) 1/0-750 MCM Cy/Al / (9) 1/0-750 MCM Cu/Al | Fixed-Mount Open with Inphase or Delayed Transition 2,000/2,500/3,200 Neutral Connection: (24) 4/0-500 MCM Cu/Al / (36) 4/0-500 MCM Cu/Al | Drawout Open with Inphase or Delayed Transition Amperes: 2,000-2,500-3,200 | Drawout Open with Inphase or Delayed Transition 2,000-2,500-3,200 Poles: 3-4/3-4 | Drawout Open with Inphase or Delayed Transition 2,000-2,500-3,200 Load Side, Normal and Standby Source: (6) 1/0-750 MCM / (9) 1/0-750 MCM | Drawout Open with Inphase or Delayed Transition 2,000-2,500-3,200 Neutral Connection: (24) 4/0-500 MCM / (36) 4/0-500 MCM | UL 1008 Withstand and Closing Ratings Ampere Rating: 2,00/2,500/3,000/3,200/4,000/5,000 | UL 1008 Withstand and Closing Ratings 2,00/2,500/3,000/3,200/4,000/5,000 Rating When Used with Upstream Circuit Breaker (3 Cycle 600V-30 Cycle 600V): 100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/-85 kA/
Operational
Operating Temperature, Maximum
-4 ° to 158 °F (-20 ° to 70 °C)
Dimensions
Height
Fixed-Mount Open with Inphase or Delayed Transition 2,000/2,500/3,200: 90.0 in (2,286 mm)/90.0 in (2,286 mm) | Drawout Open with Inphase or Delayed Transition 2,000-2,500-3,200: 90.0 in (2,286 mm)/90.0 in (2,286 mm)
Width
Fixed-Mount Open with Inphase or Delayed Transition 2,000/2,500/3,200: 32.0 in (812 mm)/44.0 in (1,117 mm) | Drawout Open with Inphase or Delayed Transition 2,000-2,500-3,200: 32.0 in (812 mm) / 44.0 in (1,117 mm)
Depth, Maximum
Fixed-Mount Open with Inphase or Delayed Transition 2,000/2,500/3,200: 48.0 in (1,219 mm)-63.0 in (1,600 mm)/48.0 in (1,219 mm)-63.0 in (1,600 mm) / 48.0 in (1,219 mm)-63.0 in (1,600 mm)/48.0 in (1,219 mm)-63.0 in (1,600 mm) | Drawout Open with Inphase or Delayed Transition 2,000-2,500-3,200: 60.0 in (1,524 mm)-75.0 in (1,905 mm)/60.0 in (1,524 mm)-75.0 in (1,905 mm) / 60.0 in (1,524 mm)-75.0 in (1,905 mm)/60.0 in (1,524 mm)-75.0 in (1,905 mm)
Weights
Weight
Fixed-Mount Open with Inphase or Delayed Transition 2,000/2,500/3,200: 1,050 lbs (477 kg)-1,600 lbs (727 kg)/1,250 lbs (568 kg)-1,800 lbs (818 kg) / 1,900 lbs (864 kg)- 2,400 lbs (1,091 kg)-2,000 lbs (909 kg)-2,500 lbs (1,136 kg) | Drawout Open with Inphase or Delayed Transition 2,000-2,500-3,200: 1,600 lbs (727 kg)-2,100 lbs (955 kg)/1,900 lbs(864 kg)-2,400 lbs (1,091 kg) / 2,500 lbs (1,136 kg)-3,000 lbs (1,364 kg)/2,800 lbs (1,273 kg)-3,300 lbs (1,500 kg)
Features
Features
Fixed-Mount Open with Inphase or Delayed Transition 2,000-2,500-3,200 Enclosure Type 8NEMA): 1-3R/1-3R / 1-3R/1-3R | Drawout Open with Inphase or Delayed Transition 2,000-2,500-3,200 Enclosure Type (NEMA): 1-3R/1-3R / 1-3R/1-3R | High Withstand and Closing Ratings | Safe Manual Transfer Under Load | Front Access | Cable or Bus Entry is Top, Bottom or Both | Isolated Compartments for Improved Safety | Mimic Diagram with Source Available and Connected LED Indication | Event Logging and Recording 450 Time-Stamped Events | System TEST Pushbutton | Programmable Plant Exerciser | Field-Selectable Multi-Tap Transformer Panel Permits Operation on a Wide Range of System Voltages | Modbus® RTU | ATC-900 Controller | Three Phase Under and Over Voltage Sensing on Normal and Emergency Sources, Plus Load | Under and Over Frequency Sensing on Normal, Emergency and Load | Three Phase Sequence Sensing for Phase Sensitive Loads | Three Phase Voltage Unbalance and Loss Sensing | Source Available: Source-1 Present, 1-N.O. and 1-N.C. / Source-2 Present, 1-N.O. and 1-N.C. | Switch Position: Source-1 Position, 1-N.O. and 1-N.C. / Source-2 Position, 1-N.O. and 1-N.C. | Up to 20 Available with Expandable Input/Output Modules | Monitor Mode | Bypass Timers | Lockout | Manual Retransfer On/Off | Manual Retransfer | Slave In | Remote Engine Test | Preferred Source Selection | Go to Emergency | Emergency Inhibit | Go to Neutral | Load Sequence | Selective Load Shed | Load Bank Control | Pre/Post-Transfer | Pre-Transfer | User Remote Control | Source 1 Available (Standard) | Source 2 Available (Standard) | Source 1 Connected | Source 2 Connected | ATS Not in Automatic | General Alarm | ATS in Test | Engine Test Aborted | Cooldown in Process | Engine Start Contact Status | Generator 1 Start Status | Generator 2 Start Status | Emergency Inhibit On