Electric
Electrical
Amperes: 1,000-2,000/2,500-3,200 | 1,000-2,000/2,500-3,200 Poles | 1,000-2,000/2,500-3,200 Load Side, Normal and Standby Source: (6) 1/0-750 MCM Cu/Al / (9) 1/0-750 MCM Cu/Al | 1,000-2,000/2,500-3,200 Neutral Connection: (24) 4/0-500 MCM Cu/Al / (36) 4/0-500 MCM Cu/Al | UL 1008 Withstand and Closing Ratings Ampere Rating: 1,000/1,200/1,600/2,000/2,500/3,200/4,000 /5,000 | UL 1008 Withstand and Closing Ratings 1,000/1,200/1,600/2,000/2,500/3,200/4,000 /5,000 Rating When Used with Upstream Circuit Breaker (3 Cycle 600 V-30 Cycle 600 V): 100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/100 kA-85 kA/-85 kA
Operational
Operating Temperature, Maximum
-4 ° to 158 °F (-20 ° to 70 °C)
Dimensions
Height
1,000-2,000/2,500-3,200: 90.0 in (2,286 mm)/90.0 in (2,286 mm)
Width
1,000-2,000/2,500-3,200: 64.0 in (1,626 mm)/64.0 in (1,626 mm)
Depth, Maximum
1,000-2,000/2,500-3,200: 60.0 in (1,524 mm)- 75.0 in (1,905 mm)/60.0 in (1,524 mm)- 75.0 in (1,905 mm) / 60.0 in (1,524 mm)- 75.0 in (1,905 mm)/60.0 in (1,524 mm)- 75.0 in (1,905 mm)
Weights
Weight
1,000-2,000/2,500-3,200: 3,100 lbs (1,409 kg)- 4,100 lbs (1,864 kg)- 3,700 lbs (1,682 kg)- 4,700 lbs (2,136 kg) / 4,700 lbs (2,136 kg)- 5,700 lbs (2,591 kg)- 5,500 lbs (2,500 kg)- 6,500 lbs (2,955 kgs)
Features
Features
1,000-2,000/2,500-3,200 Enclosure Type (NEMA): 1-3R/1-3R / 1-3R/1-3R | Single Motion Rack-out with Doors Closed | Front Access | Cable Entry is Side, Rear, Top, and Bottom | Drawout Design | Isolated Compartments for Improved Safety | Mimic Diagram with Source Available and Connected LED Indication | Field-Selectable Multi-tap Transformer Panel Permits Operation on a Wide Range of System Voltages | Event Logging and Recording 450 Time-Stamped Events | System TEST Pushbutton | Programmable Plant Exerciser | Modbus® RTU | ATC-900 Controller | Three Phase Under and Over Voltage Sensing on Normal and Emergency Sources, Plus Load | Under and Over Frequency Sensing on Normal, Emergency, and Load | Three Phase Sequence Sensing for Phase Sensitive Loads | Three Phase Voltage Unbalance and Loss Sensing | Source Available: Source-1 Present, 1-N.O. and 1-N.C. / Source-2 Present, 1-N.O. and 1-N.C. | Switch Position: Source-1 Position, 1-N.O. and 1-N.C. / Source-2 Position, 1-N.O. and 1-N.C. | Up to 20 Parameters Available with Expandable Input/Output Modules | Monitor Mode | Bypass Timers | Lockout | Manual Retransfer On/Off | Manual Retransfer | Slave In | Remote Engine Test | Preferred Source Selection | Go to Emergency | Emergency Inhibit | ATS on Bypass | Go to Neutral | Load Sequence | Selective Load Shed | Load Bank Control | Pre/Post-Transfer | Pre-Transfer | User Remote Control | Source 1 Available (Standard) | Source 2 Available (Standard) | Source 1 Connected | Source 2 Connected | ATS Not in Automatic | General Alarm | ATS in Test | Engine Test Aborted | Cooldown in Process | Engine Start Contact Status | Generator 1 Start Status | Generator 2 Start Status | Emergency Inhibit On | ATS On Bypass