2025 Generac Mobile Industrial Transfer Switches psts-100-1600a-se-rated
The Power Series Transfer Switch line features 3 different platforms with multiple technologies to offer the most flexible solutions up to 5,000 AMPs. All platforms are rated for 3 cycle operation with highly reliable mechanisms with safety interlocks. Service entrance models are 100 percent rated and available with integral overcurrent protection.
Features may include:
- Standard — Provides fast transfers and is an economical and easy-to-use choice for most facilities.
- Service Entrance — Provides a disconnect that interrupts excessive voltage and allows for manually disconnecting your facility from the electrical utility. Rated for full load transfers in critical operating, emergency, legally required, and power systems.
- Bypass Isolation — Designed for transfer switch applications where maintenance must be performed while maintaining continuous power to the load.
- Manual – Designed for applications having a need for a mobile generator, providing reliable and easy-to-use connections for safe and quick backup power connection.
- 100 – 5000 Amp
- Open with Time Delay Neutral or In-Phase Transfer
- Closed Transition
- Bypass Isolation
- Contactor, Power Frame, or Molded Case Breaker
- 2, 3, 4 Pole
- NEMA 1, 12, 3R, 4 & 4X
- UL1008/CSA/NFPA/NEC/ISO/ANSI/OSHPD/IEC
- Microprocessor Based Control
- Two Wire Start – Any Generator Controller
- Service Entrance and Non-Service Entrance Rated
Electric
Electrical
Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount Voltage: 480 and bellow / 600 | Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 480 and Bellow, Amperes: 100/150-200/225-400 | Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 600, Amperes: 100/150-200 | Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 480 and bellow 100/150-200/225-400, Transition: Open with Inphase - Open with Inphase and Delayed / Open with Inphase - Open with Inphase and Delayed / Open with Inphase - Open with Inphase and Delayed | Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 600 100/150-200, Transition: Open with Inphase / Open with Inphase - Open with Inphase and Delayed | Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 480 and bellow 100/150-200/225-400 Load Side, Normal and Standby Source: (1) #14-2/0 Cu/Al - (1) #14-2/0 Cu/Al - (1) #14-2/0 Cu/Al - (1) #14-2/0 Cu/Al / (1) #6-250 MCM Cu/Al - (1) #6-250 MCM Cu/Al - (1) #6-250 MCM Cu/Al - (1) #6-250 MCM Cu/Al / (2) 1/0-250 MCM or (1) 1/0-750 MCM Cu/Al - (2) 1/0-250 MCM or (1) 1/0-750 MCM Cu/Al - (2) 1/0-250 MCM or (1) 1/0-750 MCM Cu7Al - (2) 1/0-250 MCM or (1) 1/0-750 MC Cu/Al | Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 600 100/150-200 Load Side, Normal and Standby Source: (1) #6-250 MCM Cu/Al - (1) #6-250 MCM Cu/Al / (1) #6-250 MCM Cu/Al - (1) #6-250 MCM Cu/Al - (1) #6-250 MCM Cu/Al - (1) #6-250 MCM Cu/Al | Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 480 and bellow 100/150-200/225-400 Neutral Connection: (3) #14-1/0 Cu/Al - (3) #14-1/0 Cu/Al - (3) #14-1/0 Cu/Al - (3) #14-1/0 Cu/Al / (3) 1/0-250 MCM Cu/Al - (3) 1/0-250 MCM Cu/Al - (3) 1/0-250 MCM Cu/Al - (3) 1/0-250 MCM Cu/Al / (6) 250-500 MCM Cu/Al - (6) 250-500 MCM Cu/Al - (6) 250-500 MCM Cu/Al - (6) 250-500 MCM Cu/Al | Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 600 100/150-200 Neutral Connection: (3) #14-1/0 Cu/Al - (3) #14-1/0Cu/Al / (3) 1/0-250 MCM Cu/Al - (3) 1/0-250 MCM Cu/Al - (3) 1/0-250 MCM Cu7Al - (3) 1/0-250 MCM Cu/Al | Contactor Type, Open and Delayed Transition, 600 – 1,200A, Floor Standing, Wall Secured Voltage: 480 and bellow/600 | Contactor Type, Open and Delayed Transition, 600 – 1,200A, Floor Standing, Wall Secured amperes: 600-1,200 / 225-1,200 | Contactor Type, Open and Delayed Transition, 600 – 1,200A, Floor Standing, Wall Secured 480 and bellow/600 Load Side, Noirmal and Standby Source: (4) 1/0-750 MCM Cu/Al - (4) 1/0-750 MCM Cu/Al / (2) 1/0-250 MCM or (1) 1/0-750 MCM Cu/Al - (2) 1/0-250 MCM or (1) 1/0-750 MCM Cu/Al | Contactor Type, Open and Delayed Transition, 600 – 1,200A, Floor Standing, Wall Secured 480 and bellow/600 Neutral Connection: (12) 1/0-750 MCM Cu/Al - (12) 1/0-750 MCM Cu/Al / (6) 250-500 MCM Cu/Al - (6) 250-500 MCM Cu/Al | Contactor Type, Open and Delayed Transition, 1,600A, Freestanding Voltage: 480 and bellow | Contactor Type, Open and Delayed Transition, 1,600A, Freestanding Amperes: 1,600 | Contactor Type, Open and Delayed Transition, 1,600A, Freestanding Load Side, Normal and Standby Source: (4) 1/0-750 MCM Cu/Al - (4) 1/0-750 MCM Cu/Al | Contactor Type, Open and Delayed Transition, 1,600A, Freestanding Neutral Connection: (12) 1/0-750 MCM Cu/Al - (12) 1/0-750 MCM Cu/Al | UL 1008 Withstand and Closing Ratings Ampere Rating: 100/150-200/225-400/600-1,200/1,600 | UL 1008 Withstand and Closing Ratings 100/150-200/225-400/600-1,200/1,600 Any Breaker (0.05 sec) 480 V and Bellow Max/600 V Max: 10 kA/10 Ka - 30 kA/22 Ka / 10 kA/22 kA - 30 kA/22 Ka / 30 kA/- - 30 kA/50 kA / 50 kA/50 kA - 50 kA/- | UL 1008 Withstand and Closing Ratings 100/150-200/225-400/600-1,200/1.600 Specific Breaker 480 and Bellow Max/600 V Max: 30 kA/22 kA - 50 kA/35 kA / 30 kA/35 kA - 50 kA/35 kA / 50 kA/- - 50 kA/65 kA / 65 kA/65 kA - 65 kA/- | UL 1008 Withstand and Closing Ratings 100/150-200/225-400/600-1,200/1,600 Specific Fuse 480 V and Bellow Max: 100 kA - 200 kA / 100 kA - 200 kA / 200 kA - 200 kA / 200 kA - 200 kA | UL 1008 Withstand and Closing Ratings 100/150-200/225-400/600-1,200/1,600 Specific Fuse, Fuse Class: K5, RK5-K1, RK1-J, T/RK1, RK5, J, C, K1, K5-L–T / K5, RK5-J, K1, RK1-T/RK1, RK5, J, C, K1, K5-L-T / RK1, RK5, J, C, K1, K5-L-T/RK1, RK5, J, C, K1, K5-L-T / J, T, L, RK5-L / J, T, L, RK5-L | UL 1008 Withstand and Closing Ratings 100/150-200/225-400/600-1,200/1,600 Specific Fuse 600 V Max: 100 kA/200 kA / 200 kA/200 kA / 200 kA/200 kA / 200 kA/- | UL 1008 Withstand and Closing Ratings 100/150-200/225-400/600-1,200/1,800 Specific Fuse, Fuse Claa: K5, RK5-K1, RK-J, T/RK1, RK5, J, C, K1, K5-L-T / RK1, RK5, J, C, K1, K5-L–T/RK1, RK5, J, C, K1, K5-L-T / J, T, L, RK5-L/J, T, L, RK5-L / J, T, L, RK5 -L- - | UL 1008 Withstand and Closing Ratings 100/120-200/225-400/600-1,200/1,600 Specific Fuse, Max Fuse: 200-400-450/600-800-1,200 / 600-800-1,200/600-800-1,200 / 600-1,600/600-1,600 / 600-1,600/-
Operational
Operating Temperature, Maximum
-4 ° to 158 °F (-20 ° to 70 °C)
Dimensions
Dimensions
Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 480 and bellow 100/150-200/225-400 Horizontal: 10.3 in (260 mm) - 11.5 in (292 mm) - 13.0 in (330 mm) - 15.0 in (381 mm) / 10.3 in (260 mm) - 11.5 in (292 mm) - 13.0 in (330 mm) - 15.0 in (381 mm) / 13.0 in (330 mm) - 15.0 in (381 mm) - 13.0 in (330 mm) - 15.0 in (381 mm) | Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 600 100/150-200 Horizontal: 10.3 in (260 mm) - 11.5 in (292 mm) / 13.0 in (330 mm) - 15.0 in (381 mm) - 13.0 in (330 mm) - 15.0 in (381 mm) | Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 480 and bellow 100/150-200/225-400 Vertical: 37.4 in (950 mm) - 36.3 in (921 mm) - 47.8 in (1,215 mm) - 50.8 in (1,289 mm) / 37.4 in (950 mm) - 36.3 in (921 mm) - 47.8 in (1,215 mm) - 50.8 in (1,289 mm) / 47.8 in (1,215 mm) - 50.8 in (1,289 mm) - 47.8 in (1,215 mm) - 50.8 in (1,289 mm) | Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 600 100/150-200: 37.4 in (950 mm) - 36.3 in (921 mm) / 47.8 in (1,215 mm) - 50.8 in (1,289 mm) - 47.8 in (1,215 mm) - 50.8 in (1,289 mm)
Height
Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 480 and bellow 100/150-200/225-400: 38.7 in (983 mm) - 37.5 in (953 mm) - 52.0 in (1,321 mm) - 52.0 in (1,321 mm) / 38.7 in (983 mm) - 37.5 in (953 mm) - 52.0 in (1,321 mm) - 52.0 in (1,321 mm) / 52.0 in (1,321 mm) - 52.0 in (1,321 mm) - 52.0 in (1,321 mm) - 52.0 in (1,321 mm) | Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 600 100/150-200: 38.7 in (983 mm) - 37.5 in (953 mm) / 52.0 in (1,321 mm) - 52.0 in (1,321 mm) - 52.0 in (1,321 mm) - 52.0 in (1,321 mm) | Contactor Type, Open and Delayed Transition, 600 – 1,200A, Floor Standing, Wall Secured 480 and bellow/600: 79.4 in (2,017 mm) - 84.8 in (2,153 mm) / 79.4 in (2,017 mm) - 84.8 in (2,153 mm) | Contactor Type, Open and Delayed Transition, 1,600A, Freestanding: 90.0 in (2,286 mm) - 90.7 in (2,304 mm)
Width
Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 480 and bellow 100/150-200-225: 18.3 in (465 mm) - 17.5 in (445 mm) - 19.8 in (503 mm) - 21.0 in (533 mm) / 18.3 in (465 mm) - 17.5 in (445 mm) - 19.8 in (503 mm) - 21.0 in (533 mm) / 19.8 in (503 mm) - 21.0 in (533 mm) - 19.8 in (503 mm) - 21.0 in (533 mm) | Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 600 100/150-200: 19.8 in (503 mm) - 21.0 in (533 mm) / 19.8 in (503 mm) - 21.0 in (533 mm) - 19.8 in (503 mm) - 21.0 in (533 mm) | Contactor Type, Open and Delayed Transition, 600 – 1,200A, Floor Standing, Wall Secured 480 and bellow/600: 25.3 in (641 mm) 3-pole 29.20 in (741 mm) 4-pole - 29.0 in (737 mm) 3-pole / 29.2 in (741 mm) - 29.0 in (737 mm) 3-pole | Contactor Type, Open and Delayed Transition, 1,600A, Freestanding: 40.0 in (1,016 mm) - 40.4 in (1,025 mm)
Depth, Maximum
Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 480 and bellow 100/150-200/225-400: 13.3 in (334 mm) - 14.3 in (364 mm) - 16.8 in (426 mm) - 16.8 in (426 mm) / 13.3 in (334 mm) - 14.3 in (364 mm) - 16.8 in (426 mm) - 16.8 in (426 mm) / 16.8 in (426 mm) - 16.8 in (426 mm) - 16.8 in (426 mm) - 16.8 in (426 mm) | Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 600 100/150-200: 13.3 in (339 mm) - 14.3 in (364 mm) / 16.8 in (426 mm) - 16.8 in (426 mm) - 16.8 in (426 mm) - 16.8 in (426 mm) | Contactor Type, Open and Delayed Transition, 600 – 1,200A, Floor Standing, Wall Secured 480 and bellow/600: 22.5 in (571 mm) - 24.3 in (616 mm) / 22.5 in (571 mm) - 24.3 in (616 mm) | Contactor Type, Open and Delayed Transition, 1,600A, Freestanding: 29.0 in (737 mm) - 47.6 in (1,209 mm)
Weights
Weight
Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 480 and bellow 100/150-200/225-400: 156 lbs (71 kg) - 156 lbs (71 kg) - 250 lbs (113 kg) - 250 lbs (113 kg) / 160 lbs (73 kg) - 164 lbs (74 kg) - 250 lbs (113 kg) - 260 lbs (118 kg) / 250 lbs (113 kg) - 260 lbs (118 kg) - 250 lbs (113 kg) - 260 lbs (118 kg) | Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 600 100/150-200: 164 lbs (74 kg) - 164 lbs (74 kg) / 260 lbs (118 kg) - 260 lbs (118 kg) - 260 lbs (118 kg) - 260 lbs (118 kg) | Contactor Type, Open and Delayed Transition, 600 – 1,200A, Floor Standing, Wall Secured 480 and bellow/600: 600 lbs (272 kg) 3-pole 650 lbs (295 kg) 4-pole - 700 lb (318 kg) 3-pole 750 lba (340 kg) 4-pole / 600 lbs (272 kg) 3-pole 650 lbs (295 kg) 4-pole - 700 lbs (318 kg) 3-pole 750 lbs (340 kg) 4-pole | Contactor Type, Open and Delayed Transition, 1,600A, Freestanding: 1090 lba (494 kg) 3-pole 1150 lba (522 kg) 4-pole - 1200 lbs (544 kg) 3-pole 1260 lbs (571 kg) 4-pole
Features
Features
Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 480 and bellow 100/150-200/225-400 Enlosure Type (NEMA): 1, 3R - 4X / 1, 3R - 4X - 1, 3R - 4X / 1, 3R - 4X - 1, 3R - 4X | Contactor Type, Open and Delayed Transition, 100 – 600 A, Wall Mount 600 100/150-200 Enclosure Type (NEMA): 1, 3R - 4X / 1, 3R - 4X / 1, 3R - 4X | Contactor Type, Open and Delayed Transition, 600 – 1,200A, Floor Standing, Wall Secured 480 and bellow/600 Transition: Open with Inphase and Delayed/Open with Inphase and Delayed | Contactor Type, Open and Delayed Transition, 600 – 1,200A, Floor Standing, Wall Secured 480 and Bellow Enclosure Type (NEMA): 1, 3R/4X | Contactor Type, Open and Delayed Transition, 600 – 1,200A, Floor Standing, Wall Secured 600 Enclosure Type (NEMA): 1, 3R/4X | Contactor Type, Open and Delayed Transition, 1,600A, Freestanding Transitions: Open Inphase and Delayed | Contactor Type, Open and Delayed Transition, 1,600A, Freestanding Enclosure Type (NEMA): 1-3R | UL 1008 Withstand and Closing Ratings 100/150-200/225-400/600-1,200/1,600 Transition: Open with Inphase Only - Open with Inphase and Delayed / Open with Inphase Only - Open with Inphase and Delayed / Open with Inphase Only - Open with Inphase and Delayed / Open with Inphase and Delayed - Open with Inphase and Delayed | Double-Throw, Solenoid-Operated Transfer Mechanism | LCD-Based Display for Programming, System Diagnostics and Help Menu Display | Mimic Diagram with Source Available and Connected LED Indicator | Time-Stamped History Log | System TEST Pushbutton | Programmable Plant Exerciser - OFF, Daily, 7, 14, 28 Day Interval Selectable Run Time 0-600 Minutes No Load/Load with Failsafe | Methods of Transfer Include: Open with Inphase Transition Only, Time Delay in Neutral Transition, or Inphase with a Default to Time Delay in Neutral Transfer | Mechanically Interlocked to Prevent Connection of Both Sources | Field-Selectable Multi-Tap Transformer Panel Permits Operation on a Wide Range of System Voltages | Modbus® RTU | ATC-300+ Controller | Three Phase Under and Over Voltage Sensing on Normal and Emergency Sources | Under and Over Frequency Sensing on Normal and Emergency | Phase Sequence Sensing for Phase Sensitive Loads | Source Available: Source-1 Present, 2-N.O. and 2-N.C. / Source-2 Present, 2-N.O. and 2-N.C. | Switch Position: Source-1 Position, 1-N.O. and 1-N.C. / Source-2 Position, 1-N.O. and 1-N.C. | Pre-Transfer Signal Contacts 1-N.O. and 1-N.C.