Generac’s 1200-1600A Service Entrance Rated (SE) TX Series transfer switches are designed to meet the evolving demands of Mission Critical markets. This product delivers reliable performance with high WCR (Withstand Close-On Ratings) capabilities, ensuring smooth coordination for engineers and a seamless power transfer experience. Key applications benefit from the reduced footprint of this 100%-rated switch, allowing for cost-efficient and compact installations without the need to oversize equipment.
Features may include:
Size Offering:- Available in 1200-1600A, accommodating up to 480 VAC and 60 Hz.
- Designed with 100kA WCR, ensuring robust performance and peace of mind during breaker coordination studies.
- Double-throw robust construction utilizing a patented contactor-type design for durability and reliability.
- Includes front-accessible controls with USB functionality and 60 minutes of built-in battery backup.
- 100% rated switch eliminates oversizing, reducing both installation costs and physical space requirements.
- The TX 1200-1600A SE transfer switch is designed for:
- Healthcare Facilities: Supporting life-saving equipment and critical loads.
- Data Centers: Maintaining continuous operation and uptime.
- Retail and Manufacturing Facilities: Ensuring seamless transitions during outages.
- ETL Certified to UL 1008: Built to exceed U.S. standards for safe and reliable operations.
Electric
Electrical
1200A 3 Pole Normal 75 °C Wire: (4) 4/0-500MCM or (3) 500-750MCM |1200A 3 Pole Standby Source 75 °C Wire: (4) 750 – 4/0 | 1200A 3 PoleLoad 75 °C Wire: (4) 750 – 4/0 | 1200A 3 Pole Neutral Connection: (12) 750 – 1/0 | 1200A 3 Pole Ground Connection: (15) 600-#4 or (30) 250-1/0 | 1200A 3 Pole Ampere Rating: 1200 A /1600 A | 1200A 3 Pole WCR Ratings: 100 kA / 100 kA | 1200A 3 Pole: 480 V / 480 V | 1200A 4 Pole Normal 75 °C Wire: (4) 4/0-500MCM or (3) 500-750MCM | 1200A 4 PoleStandby Source 75 °C Wire: (4) 750 – 4/0 | 1200A 4 PoleStandby Source 75 °C Wire: (4) 750 – 4/0 | 1200A 4 PoleLoad 75 °C Wire: (4) 750 – 4/0 | 1200A 4 PoleNeutral Connection (4) 750 – 1/0 | 1200A 4 Pole Ground Connection: (15) 600-#4 or (30) 250-1/0 | 1200A 4 Pole Ampere Rating: 1200 A / 1600 A | 1200A 4 Pole WCR Ratings: 100 kA | 1200A 4 Pole: 480 V | 1600A 3 Pole Normal 75 °C Wire: (4) 500 – 1000 | 1600A 3 Pole Standby Source 75 °C Wire: (6) 750 – 4/0 | 1600A 3 Pole Load 75 °C Wire: (6) 750 – 4/0 | 1600A 3 Pole Neutral Connection: (20) 750 – 1/0 | 1600A 3 Pole Ground Connection: (20) 600-#4 or (40) 250-1/0 | 1600A 3 Pole Ampere Rating: 1200 A / 1600 A | 1600A 3 Pole WCR Ratings: 100 kA | 1600A 3 Pole Voltage: 480 V | 1600A 4 Pole Normal 75 °C Wire: (4) 500 – 1000 | 1600A 4 Pole Standby Source 75 °C Wire: (6) 750 – 4/0 | 1600A 4 Pole Load 75 °C Wire: (6) 750 – 4/0 | 1600A 4 Pole Neutral Connection: (8) 750 – 1/0 | 1600A 4 Pole Ground Connection: (20) 600-#4 or (40) 250-1/0 | 1600A 4 Pole Ampere Rating: 1200 A / 1600 A | 1600A 4 Pole WCR Ratings: 100 kA | 1600A 4 Pole Voltage: 480 V
Dimensions
Dimensions
1200A 3 Pole: 16 in (407 mm) / 3.6 in (91 mm) / 33.7 in (856 mm) / 26.2 in (666 mm) / 27.6 in (701 mm) / 28.9 in (733 mm) / 30.3 in (768 mm) / 46.1 in (1172 mm) / 22.2 in (563 mm) / 26.2 in (665 mm) / 27.6 in (700 mm) / 40 in (1017 mm) / 2.4 in (62 mm) / 4.4 in (111 mm) / 6.9 in (175 mm) / 8.9 in (225 mm) / 16.6 in (421 mm) | 1200A 4 Pole: 16 in (407 mm) / 3.6 in (91 mm) / 33.7 in (856 mm) / 26.2 in (666 mm) / 27.6 in (701 mm) / 28.9 in (733 mm) / 30.3 in (768 mm) / 46.1 in (1172 mm) / 75.3 in (1914 mm) / 74.5 in (1891 mm) / 75.7 in (1923 mm) / 19.6 in (498 mm) / 40 in (1017 mm) / 2.4 in (62 mm) / 4.4 in (111 mm) / 6.9 in (175 mm) / 8.9 in (225 mm) / 16.6 in (421 mm) | 1600A 3 Pole: 14.2 in (360 mm) / 4.8 in (123 mm) / 40.2 in (1021 mm) / 24.1 in (611 mm) / 25.4 in (646 mm) / 26.7 in (677 mm) / 28.1 in (713 mm) / 45.2 in (1149 mm) / 24.6 in (624 mm) / 28.6 in (726 mm) / 30 in (761 mm) / 20.2 in (512 mm) / 2.7 in (68 mm) / 4.6 in (118 mm) / 7.2 in (182 mm) / 9.1 in (231 mm) / 13.7 in (348 mm) | 1600A 4 Pole: 19 in (483 mm) / 4.8 in (123 mm) / 45 in (1144 mm) / 24.1 in (611 mm) / 24.5 in (646 mm) / 26.7 in (677 mm) / 28.1 in (713 mm) / 45.2 in (1149 mm) / 76.6 in (1944 mm) / 75.7 in (1922 mm) / 78.3 in (1989 mm) / 20.2 in (512 mm) / 2.7 in (68 mm) / 4.6 in (118 mm) / 7.2 in (182 mm) / 9.1 in (231 mm) / 13.7 in (348 mm)
Weights
Weight
1200A 3 Pole: 880 lbs (399.1 kg) | 1200A 4 Pole: 980 lbs (44 kg) | 1600A 3 Pole: 1275 lbs (578 kg) | 1600A 4 Pole: 1385 lbs (628 kg)
Features
Features
Floor Mounted, Wall Secured | Cable Entry is Top or Bottom | Double-Throw, Stored Energy Transfer Mechanism | Graphical LCD-Based Display for Programming, System Diagnostics and Help Menu Display Mimic | Diagram with Source Available and Connected | Method of Transfer: Open with Inphase Transition and Delayed Transition | Mechanically Interlocked to Prevent Connection of Both Sources | Modbus® RTU | TXC 100 Controller | Operating Temperature -4 ° to 158 °F (-20 ° to 70 °C) | Voltage Agnostic | High Withstand and Closing Ratings | Heater Kit Standard on All 3R Enclosures | Auxiliary Input Includes: Permissive Inputs (24VDC) | General Alarm Indication | Three Phase Under and Over Voltage Sensing on Normal and Emergency Sources | Under and Over Frequency Sensing on Normal and Emergency | Selectable Settings: Single or Three Phase Voltage | Sensing on Normal and Emergency 60 Hz | Phase Sequence Sensing for Phase Sensitive Loads | 2-wire Start | 3-wire Start from C Contact for Circuit Monitoring | Switch Position Indication (2 Form C) | Signal Before Transfer (Elevator) | General Alarm | Programmable Output | Emergency Inhibit (Permissive & Load Shed) | Go to Emergency | Manual Generator Retransfer | Front Programmable Control Reduces PPE Needs and Arc Flash Hazard | Built in Battery Backup – Increases Switch Reliability and Reduces Switch Transition Time to Alternate Source | Battery Backup Able to Power the Controller for up to 60 Minutes in the Event of No Source Availability | Accessible USB Port for Easy Data Downloads, Firmware Updates without Requiring PPE, Reducing the Risk of Arc Flash| Heater Programmable through Control for Desired Temperature and Humidity Settings | Front Accessible Customer Connections | Time-Stamped Event History Log | Programmable Exerciser – Daily, Weekly, Biweekly, Monthly
Warranty
Warranty
2 Year Limited Warranty